5-56
1
By adding an encoder (PG) to the application, a faster and more speed search would
occur.
07-13
Speed Search Frequency (FWD direction)
Factory setting 60.00/50.00
Settings
0.00~400.00Hz
1
This parameter is used as the frequency start point for the Speed Search function, when
Pr. 07-12 is set to 2 or 4.
07-14
Speed Search Frequency (REV direction)
Factory setting 60.00/50.00
Settings
0.00~400.00Hz
1
This parameter is used as the frequency start point for the Speed Search function when
Pr. 07-12 is set to 3 or 5.
Speed Search type
07-12
current
07-09
*
07-13
Speed search
frequency
(forward direction)
07-14
Frequency
Speed search
frequency
(REV direction)
07-15
Gear Gap Acceleration-Interruption Time
Factory setting
0.00
Settings
0.00~400.00 s
07-16
Gear Gap Acceleration-Interruption Frequency
Factory setting
6.00
Settings
0.00~400.00Hz
07-17
Gear Gap Deceleration-Interruption Time
Factory setting
0.00
Settings
0.00~400.00 s
07-18
Gear Gap Deceleration-Interruption Frequency
Factory setting
6.00
Settings
0.00~400.00Hz
1
These parameters determine the time and frequency point for the drive to stop
acceleration or deceleration to allow the motor to catch up to the ac drives output
frequency. This is commonly used with heavy loaded applications where the motors
rotor is lagging the stator.