4-24
Parameters
Functions
Settings
Factory
Setting
Customer
06-17
Most Recent Fault Record
0: no fault
1: oc (over-current)
2: ov (over-voltage)
3: oH1 (IGBT overheat)
4: oL (drive overload)
5: oL1 (electronic thermal
relay)
6: EF (external fault)
7: CF3 (hardware circuit fault)
8: HPF (protection circuit fault)
0
06-18
2
nd
Most Recent Fault
Record
9: ocA (over-current during
accel)
10: ocd (over-current during
decel)
11: ocn (over-current during
constant speed)
12: GFF (ground fault)
13: pg error
14: Lv (low voltage)
15: CF1 (unable to write to
memory)
16: CF2 (unable to read
memory)
17: bb (Pause)
0
06-19
3
rd
Most Recent
Fault Record
18: oL2 (motor overload)
19: sc (IGBT failure)
20: brake (braking transistor
failure)
21: OL3 (motor overload)
22: oh2 (brake overheat)
23: Fuse failure
24: CT2 (current sensor 2)
25: CT1 (current sensor 1)
26: PWM (upper and lower
points at the same low level)
27: Motor auto tuning failure
0
06-20
4
th
Most Recent Fault
Record
28: pid error
29: ACI error
31: CC
33: VEC R1 out of range (Pr.
05-30)
34: keypad error
35: RS 485 watchdog timer
36: FAN failure
37: input phase loss
0