5-19
02-01
Multi-Function Input Command 1 (MI1) (NOTE 1)
Factory setting 1
02-02
Multi-Function Input Command 2 (MI2)
Factory setting 2
02-03
Multi-Function Input Command 3 (MI3)
Factory setting 3
02-04
Multi-Function Input Command 4 (MI4)
Factory setting 4
02-05
Multi-Function Input Command 5 (MI5)
Factory setting 5
02-06
Multi-Function Input Command 6 (MI6) (NOTE 2)
Factory setting 10
02-23
Multi-Function Input Command 7
Factory setting 0
02-24
Multi-Function Input Command 8
Factory setting 0
02-25
Multi-Function Input Command 9
Factory setting 0
02-26
Multi-Function Input Command 10
Factory setting 0
02-27
Multi-Function Input Command 11
Factory setting 0
02-28
Multi-Function Input Command 12
Factory setting 0
02-29
Multi-Function Input Command 13
Factory setting 0
02-30
Multi-Function Input Command 14
Factory setting 0
Settings
0 to 44
1
This parameter selects the functions for each multi-function terminal.
Note 1: If Pr.02-00 is set to 3-wire operation control. Terminal MI1 is needed for the third
wire position. Therefore MI1 is not allowed for any other operation.
Note 2: Multi-Function Input Commands 7-14 are the extension terminals of 02-01-02-06.
There are 14 terminals but the terminals 7-14 are virtual terminals and you can set
the state of bit 8-15 of 02-10 to ON or OFF by IP06 or communication.
Full List of the Functions
Settings Functions
Explanations
0
No
Function
1
Multi-step Speed Command 1
2
Multi-step Speed Command 2
3
Multi-step Speed Command 3
4
Multi-step Speed Command 4
15 step speeds could be conducted through the
digital statuses of the 4 terminals, and 17 in total if
the master speed and JOG are included.
5
Reset
After the error of the drive is eliminated, use this
terminal to reset the drive
6
JOG Command
JOG operation