4-20
Group 5: Motor Parameter
Parameters
Functions
Settings
Factory
Setting
Customer
05-00
Motor
Auto
Tuning
0: no function
1: measures (R1, R2, Lm, Lc,
no-load current)
2: measures (R1, R2, Lc)
3: measures (R1, R2, Lc, Lm,
calculated by the motor’s
no-load current)
0
05-01
Full-Load Current of Motor
1
****A(30~120%)
A
xx.x
05-02
No-Load Current of Motor 1 XXXA (5~90%)
A xx.x
05-03
Torque Compensation of
Motor 1 (for the V/F Mode
Only)
0.0~25.0%
0.0
05-04
Slip Compensation of Motor
1 (for V/F mode only)
0.0~10.0%
0.0
05-05
Number of Poles for Motor
1
2~20
4
05-06
Line to Line resistance R1
of Motor 1
m
*
Xx
05-07
Rotor resistance R2 of
Motor 1
m
*
Xx
05-08
LM of Motor 1
MH
Xx
05-09
LC of Motor 1
MH
Xx
05-10
Iron Loss of Motor 1
0.0~10.0%
1.5
05-11
Full-Load Current of Motor
2
****A (30~120%)
A xx.x
05-12
No-Load Current of Motor 2 XXXA
5~90%
A xx.x
05-13
Torque Compensation of
Motor 2
0.0~25.0%
0.0
05-14
Slip Compensation of Motor
2
0.0~10.0%
0.0
05-15
Number of Poles for Motor
2
2~20
4
05-16
Line to Line resistance R1
of Motor 2
m
*
Xx
05-17
Rotor resistance R2 of
Motor 2
m
*
Xx
05-18
LM of Motor 2
MH
Xx
05-19
LC of Motor 2
MH
Xx
05-20
Iron Loss of Motor 2
0.0~10.0%
1.5