0172
Even though the machine
carries out the regular
movement, the output of
Supply Pump 3 Sensor
does not reach the
expected value.
Check Cable connection of Servo Board
Check Cable connection of Junction Board
Check Supply Pump 3 Magnet
Supply Pump 3 Motor replacement
Supply Pump 3 Sensor replacement
Wiring or Flexible Cable replacement
Pump Board replacement
Servo Board replacement
0173
Even though the machine
carries out the regular
movement, the output of
Supply Pump 4 Sensor
does not reach the
expected value.
Check Cable connection of Servo Board
Check Cable connection of Junction Board
Check Supply Pump 4 Magnet
Supply Pump 4 Motor replacement
Supply Pump 4 Sensor replacement
Wiring or Flexible Cable replacement
Pump Board replacement
Servo Board replacement
0174
Even though the machine
carries out the regular
movement, the output of
Supply Pump 5 Sensor
does not reach the
expected value.
Check Cable connection of Servo Board
Check Cable connection of Junction Board
Check Supply Pump 5 Magnet
Supply Pump 5 Motor replacement
Supply Pump 5 Sensor replacement
Wiring or Flexible Cable replacement
Pump Board replacement
Servo Board replacement
0175
Even though the machine
carries out the regular
movement, the output of
Supply Pump 6 Sensor
does not reach the
expected value.
Check Cable connection of Servo Board
Check Cable connection of Junction Board
Check Supply Pump 6 Magnet
Supply Pump 6 Motor replacement
Supply Pump 6 Sensor replacement
Wiring or Flexible Cable replacement
Pump Board replacement
Servo Board replacement
0180
Even though the machine
carries out the regular
movement, the output of
Maintenance Liquid Pump
Sensor does not reach the
expected value.
Check Cable connection of Servo Board
Check Cable connection of Junction Board
Maintenance Liquid Pump Motor replacement
Maintenance Liquid Pump Sensor replacement
Wiring or Flexible Cable replacement
Servo Board replacement
0190
Thermistor under the BED
has a problem.
Thermistor replacement
Check Cable connection
Heater Board replacement
0200
Head 1 is abnormally hot.
Head 1 temperature has
reached 58°C and above.
Check Flexible Cable connection around Head
Check Cable connection around Heater
Head replacement
0201
Head 2 is abnormally hot.
Head 2 temperature has
reached 58°C and above.
Check Flexible Cable connection around Head
Head replacement
0202
Head 3 is abnormally hot.
Head 3 temperature has
reached 58°C and above.
Check Flexible Cable connection around Head
Head replacement
0203
Head 4 is abnormally hot.
Head 4 temperature has
reached 58°C and above.
Check Flexible Cable connection around Head
Head replacement
0204
Head 5 is abnormally hot.
Head 5 temperature has
reached 58°C and above.
Check Flexible Cable connection around Head
Head replacement
0205
Head 6 is abnormally hot.
Head 6 temperature has
reached 58°C and above.
Check Flexible Cable connection around Head
Head replacement
Thermistor (Head) has a problem.
Flexible Cable has short circuitted or cut-line.
Supply Pump 3 Motor has a problem.
Supply Pump 3 Sensor has a problem.
Supply Pump 3 Magnet has dropped out.
Wiring or Flexible Cable has short circuitted
or cut-line.
Pump Board has a problem.
Servo Board has a problem.
Thermistor (Head) has a problem.
Flexible Cable has short circuitted or cut-line.
Thermistor (Head) has a problem.
Flexible Cable has short circuitted or cut-line.
6-14
Supply Pump 4 Motor has a problem.
Supply Pump 4 Sensor has a problem.
Supply Pump 4 Magnet has dropped out.
Wiring or Flexible Cable has short circuitted
or cut-line.
Pump Board has a problem.
Servo Board has a problem.
Supply Pump 5 Motor has a problem.
Supply Pump 5 Sensor has a problem.
Supply Pump 5 Magnet has dropped out.
Wiring or Flexible Cable has short circuitted
or cut-line.
Pump Board has a problem.
Servo Board has a problem.
Supply Pump 6 Motor has a problem.
Supply Pump 6 Sensor has a problem.
Supply Pump 6 Magnet has dropped out.
Wiring or Flexible Cable has short circuitted
or cut-line.
Pump Board has a problem.
Servo Board has a problem.
Maintenance Liquid Pump Motor has a
problem.
Maintenance Liquid Pump Sensor has a
problem.
Maintenance Liquid Pump Magnet has
dropped out.
Wiring or Flexible Cable has short circuitted
Device has a problem.
Thermistor Cable has short circuited or cut-
line.
Thermistor (Head) has a problem.
Flexible Cable has short circuitted or cut-line.
Wiring of Head Heater has a problem.
Thermistor (Head) has a problem.
Flexible Cable has short circuitted or cut-line.
Thermistor (Head) has a problem.
Flexible Cable has short circuitted or cut-line.
Summary of Contents for Advanced Jet AJ-1000
Page 2: ...Revision NO Date Description of Changes Approval Issued 0 2006 7 4 First Edition Kato Mabuchi ...
Page 43: ...2 12 Arrangement Diagram_ Soldering Side ...
Page 51: ...2 20 Arrangement Diagram_ Soldering Side ...
Page 58: ...2 27 It indicates the version of the Heater Board ...
Page 66: ...2 35 It indicates the version of the Pump Drive Board ...
Page 74: ...2 43 It indicates the version of the Sub Board ...
Page 75: ...2 44 CN302 Arrangement Diagram_ Soldering Side ...
Page 76: ...2 45 U650 U700 U750 CN800 CN60 0 ...
Page 288: ......