6-12 THE BLOWER FAN DOES NOT MOVE
NO
CHECKING POINT
ACTION
REFERENCE
OUTLINE
1
Check the setting of the
blower fan
Turn on the setting of
the blower fan
User's Manual
The blower fan does not work unless turn on the setting of [BLOWER
FAN] in the heater menu.
2
Check the setting of the
dryer temperature
Change the dryer
temperature except
User's Manual
The blower fan does not move when the setting of dryer temperature is
OFF.
3
Check if the heater control
board is broken
Replace the fuse on the
heater control board
Replace the heater
control board
The heater does not work correctly because the signal to the heater is
not transferred correctly.
6-13 THE TAKE-UP/FEED OUT UNIT DOES NOT MOVE
NO
CHECKING POINT
ACTION
REFERENCE
OUTLINE
1
Check the power switch in
the take-up/feed out unit
Turn on the power
switch
The take-up/feed out unit does not move when the power switch is OFF
in the take-up/feed out unit.
2
Check whether the cover
of the take-up/feed out
unit is open or closed
Close the cover of the
take-up/feed out unit
The take-up/feed out unit does not move if the cover is open due to the
cause that the shaft is not placed correctly.
3
Check the setting of
AUTO switch
Check the setting of
AUTO switch
The take-up/feed out unit does not move automatically when AUTO
switch is OFF.
4
Check the way of the
media installation
Install the media
correctly
The take-up/feed out unit does not reflect if the media is not passed
through the guide roller and dancer roller correctly.
5
Check the cable
connection/bad contact
Check the cable
connection/bad contact
Replace the cable
[3-14 TU BOARD
REPLACEMENT]
Check the connection/bad contact the cable between AC junction board
and the take-up/feed unit. Check this when the same symptom occurs
after removing AC junction board especially.
Replace the cable if there is a problem in the cable connection/bad
contact.
6
Check the board of take-
up/feed out unit side
Replace the board of
take-up/feed out unit
[3-14 TU BOARD
REPLACEMENT]
The take-up/feed out unit does not move if the problem occurs in the
take-up/feed out unit side.
6-10
Summary of Contents for Advanced Jet AJ-1000
Page 2: ...Revision NO Date Description of Changes Approval Issued 0 2006 7 4 First Edition Kato Mabuchi ...
Page 43: ...2 12 Arrangement Diagram_ Soldering Side ...
Page 51: ...2 20 Arrangement Diagram_ Soldering Side ...
Page 58: ...2 27 It indicates the version of the Heater Board ...
Page 66: ...2 35 It indicates the version of the Pump Drive Board ...
Page 74: ...2 43 It indicates the version of the Sub Board ...
Page 75: ...2 44 CN302 Arrangement Diagram_ Soldering Side ...
Page 76: ...2 45 U650 U700 U750 CN800 CN60 0 ...
Page 288: ......