4-36
Select [PRINT MENU] > [CALIB. DEFAULT] > [SETTING] in
SERVICE MENU and change the value with [ ] and [ ]
keys.
Press [ENTER] key to save the setting.
5
6
FORMULA
CA = CL - ML
ML
x 100
Calculate the amount to be calibrated with the formula
shown at the right figure.
1. CA = Calibrating Amount
2. CL = Commanded Length (=400mm)
3. ML = Measured Length
Parameters can be entered with an increment of
0.05%.
(MAX. +2.00% ~ MIN. -2.00%)
[ ]
[ ]
SERVICE MENU
PRINT MENU
PRINT MENU
CALIB. DEFAULT
CALIB. DEFAUL
SETTING
[ ]
[ENTER]
SETTING
+0.05 > +0.10