5-30
Remove the syringe from Ink Tube and drain the ink
to the
drain bottle through the Funnel.
11
When the syringe becomes filled with the ink, select [I/S
MENU] > [I/S CONTROL] > [PRESS PUMP 1- 6] > [CLOSE]
and press [ENTER] key.
SERVICE MENU
I/S MENU
I/S MENU
I/S CONTROL
I/S CONTROL
PRESS PUMP1
[ENTER]
PRESS PUMP1
CLOSE
[ ] [ ]
[ ] [ ]
10
12
Repeat the step from 7 to 11 4 or 5 times to remove
air.
When the ink in Sub Tank reaches to empty duing pulling
the ink, s
elect [I/S MENU] > [I/S CONTROL] > [SUPPLY
PUMP 1- 6] > [SUPPLY] and press [ENTER] key. [SUPPLY]
is stopped automatically when Sub Tank becomes full.
SERVICE MENU
I/S MENU
I/S MENU
I/S CONTROL
I/S CONTROL
SUPPLY PUMP1
[ENTER]
SUPPLY PUMP1
SUPPLY
[ ] [ ]
[ ] [ ]