0110
Input value from Linear
Encoder is not changed
when Linear Encoder is
setup the origin.
When Motor stops during
printing, Motor does not
complete the movement
which is supposed to be
done.
Confirm whether Encoder Scale is between the slit of Encoder Module
in a whole width of the machine
Check Cable connection between Linear Encoder Board and Print
Carriage Board
Confirm connection between Wire and Head Carriage
Linear Encoder replacement
Scan Motor replacement
Main Board replacement
0120
There is a problem with
Thermistor for Pre-Heater
F.
Check Cable connection around Thermistor
Thermistor replacement
0121
There is a problem with
thermistor for Pre-Heater
R.
Check Cable connection around Thermistor
Thermistor replacement
0125
Heater is unusually hot.
Pre-Heater F temperature
has reached 60°C and
above.
Check Heater
Check Thermostat
Check Thermistor
0126
Heater is unusually hot.
Pre-Heater F temperature
has reached 60°C and
above.
Check Heater
Check Thermostat
Check Thermistor
0130
There is a problem with
Thermistor for Print
Heater.
Check Cable connection around Thermistor
Thermistor replacement
0135
Heater is unusually hot.
Print Heater temperature
has reached 60°C and
above.
Check Heater
Check Thermostat
Check Thermistor
0140
There is a problem with
Thermistor for dryer (2
lines/upper).
Check Cable connection around Thermistor
Thermistor replacement
0141
There is a problem with
Thermistor for dryer (2
lines/middle).
Check Cable connection around Thermistor
Thermistor replacement
0142
There is a problem with
Thermistor for dryer (2
lines/lower).
Check Cable connection around Thermistor
Thermistor replacement
0145
Heater is unusually hot.
Dryer (2 lines/upper)
temperature has reached
80°C and above.
Check Heater
Check Thermostat
Check Thermistor
0146
Heater is unusually hot.
Dryer (2 lines/middle)
temperature has reached
80°C and above.
Check Heater
Check Thermostat
Check Thermistor
0147
Heater is unusually hot.
Dryer (2 lines/lower)
temperature has reached
80°C and above.
Check Heater
Check Thermostat
Check Thermistor
0150
Even though the machine
carries out the regular
movement, the output of
Slider Sensor does not
reach the expected value.
Check Cable connection of Servo Board
Check Cable connection of Junction Board
Slider Motor replacement
Slider Sensor replacement
Wiring or Flexible Cable replacement
Servo Board replacement
0151
Even though the machine
carries out the regular
movement, the output of
Head Rise and Fall
Sensor does not reach the
expected value.
Check Cable connection of Servo Board
Check Cable connection of Junction Board
Head Rise and Fall Motor replacement
Head Rise and Fall Sensor replacement
Wiring or Flexible Cable replacement
Servo Board replacement
0152
Even though the machine
carries out the regular
movement, the output of
Wiper Sensor does not
reach the expected value.
Check Cable connection of Servo Board
Check Cable connection of Junction Board
Wiper Motor replacement
Wiper Sensor replacement
Wiring or Flexible Cable replacement
Servo Board replacement
Slider Motor has a problem.
Slider Sensor has a problem.
Wiring or Flexible Cable has short circuitted
or cut-line.
Servo Board has a problem.
Head Rise and Fall Motor has a problem.
Head Rise and Fall Sensor has a problem.
Wiring or Flexible Cable has short circuitted
or cut-line.
Servo Board has a problem.
Wiper Motor has a problem.
Wiper Sensor has a problem.
Wiring or Flexible Cable has short circuitted
or cut-line.
Servo Board has a problem.
Device has a problem.
Thermistor Cable has short circuited or cut-
line.
Device has a problem.
Thermistor Cable has short circuited or cut-
line.
Heater Cable connection has a problem.
Thermostat has a problem (not working).
Thermistor has a problem.
Heater Cable connection has a problem.
Thermostat has a problem (not working).
Thermistor has a problem.
6-12
Read error of Linear Encoder.
Read error of Encoder on Scan Motor side.
Wire is not fixed to Head Carriage firmly.
Device has a problem.
Thermistor Cable has short circuited or cut-
line.
Device has a problem.
Thermistor Cable has short circuited or cut-
line.
Heater Cable connection has a problem.
Thermostat has a problem (not working).
Thermistor has a problem.
Heater Cable connection has a problem.
Thermostat has a problem (not working).
Thermistor has a problem.
Device has a problem.
Thermistor Cable has short circuited or cut-
line.
Heater Cable connection has a problem.
Thermostat has a problem (not working).
Thermistor has a problem.
Device has a problem.
Thermistor Cable has short circuited or cut-
line.
Heater Cable connection has a problem.
Thermostat has a problem (not working).
Thermistor has a problem.
Summary of Contents for Advanced Jet AJ-1000
Page 2: ...Revision NO Date Description of Changes Approval Issued 0 2006 7 4 First Edition Kato Mabuchi ...
Page 43: ...2 12 Arrangement Diagram_ Soldering Side ...
Page 51: ...2 20 Arrangement Diagram_ Soldering Side ...
Page 58: ...2 27 It indicates the version of the Heater Board ...
Page 66: ...2 35 It indicates the version of the Pump Drive Board ...
Page 74: ...2 43 It indicates the version of the Sub Board ...
Page 75: ...2 44 CN302 Arrangement Diagram_ Soldering Side ...
Page 76: ...2 45 U650 U700 U750 CN800 CN60 0 ...
Page 288: ......