![Rohde & Schwarz SMF-B1 Operating Manual Download Page 581](http://html1.mh-extra.com/html/rohde-and-schwarz/smf-b1/smf-b1_operating-manual_1477740581.webp)
Remote Control Commands
R&S
®
SMF100A
566
Operating Manual 1167.2319.02 ─ 12
[:SOURce<hw>]:SWEep:POWer:MARKer:AOFF
The command switches off all level markers. The command triggers an event and
therefore has no query form and no *RST value.
Example:
SOUR:SWE:POW:MARK:AOFF
switches off all level markers.
Usage:
Event
[:SOURce<hw>]:SWEep:POWer:MARKer<ch>:POWer
<Power>
The command sets the level of the selected marker. If the marker is switched on, the
signal level at the MARKER output changes on reaching the level mark.
Parameters:
<Power>
float
*RST:
0
Default unit: dBm
Example:
SOUR:SWE:POW:MARK1:POW -50
sets the power mark for marker 1 to -50 dBm.
Manual operation:
See
[:SOURce<hw>]:SWEep:POWer:MARKer<ch>:STATe
<State>
The command switches on or off the selected marker. If the marker is switched on, the
signal level at the MARKER output changes on reaching the level mark.
Parameters:
<State>
0 | 1 | OFF | ON
*RST:
OFF
Example:
SWE:POW:MARK1:STAT ON
switches on marker 1.
Manual operation:
See
[:SOURce<hw>]:SWEep:POWer:MODE
<Mode>
Sets the cycle mode of the level sweep.