16. Base DN for Search - Enter the name you want to bind against the
LDAP/LDAPS (up to 31 characters), and where in the database to
begin searching for the specified Base DN. An example Base Search
value might be:
cn=Users,dc=raritan,dc=com
. Consult your AA
server administrator for the appropriate values to enter into these
fields.
17. Type the following information in the corresponding fields. LDAP
needs this information to verify user names and passwords.
Login name attribute (also called AuthorizationString)
User entry object class
User search subfilter (also called BaseSearch)
Note: The EMX will preoccupy the login name attribute and user
entry object class with default values, which should not be changed
unless required.
18. Active Directory Domain - Type the name of the Active Directory
Domain. For example, testradius.com. Consult with your Active
Directory Administrator for a specific domain name.
19. To verify if the authentication configuration is set correctly, you may
click Test Connection to check whether the EMX can connect to the
remote authentication server successfully.
Tip: You can also do this by using the Test Connection button in the
Authentication Settings dialog.
20. Click OK. The new LDAP server is listed in the Authentication
Settings dialog.
21. To add additional LDAP/LDAPS servers, repeat Steps 3 to 20.
22. Click OK. The LDAP authentication is now in place.
To duplicate LDAP/LDAPS server settings:
If you have added any LDAP/LDAPS server information to the EMX, and
the server you are adding shares identical or similar settings with an
existing server, the most convenient way is to duplicate that
LDAP/LDAPS server's data.
1. Repeat Steps 1 to 4 in the above procedure to add the LDAP/LDAPS
server you want.
2. Select the "Use settings from LDAP Server" checkbox.
3. Click the drop-down arrow below the checkbox to select the
LDAP/LDAPS server whose settings you want to copy.
4. Make necessary changes to the information shown.
5. Click
OK.
Summary of Contents for EMX2-888
Page 19: ...Chapter 1 Introduction 5 Retrieval of the link local IPv4 address See IPv4 Address on page 72...
Page 71: ...Chapter 4 Connecting External Equipment Optional 57...
Page 148: ...Chapter 6 Using the Web Interface 134 LHX 20 SHX 30 LHX 40 PowerLogic PM710...
Page 526: ...Appendix H RADIUS Configuration Illustration 512 Note If your EMX uses PAP then select PAP...
Page 531: ...Appendix H RADIUS Configuration Illustration 517 14 The new attribute is added Click OK...
Page 532: ...Appendix H RADIUS Configuration Illustration 518 15 Click Next to continue...