Chapter 9: Troubleshooting
Resetting Factory Defaults
Quantum Scalar i40 and Scalar i80 User’s Guide
261
Robotics Get/Put Test
The Get/Put Test requires the robot to remove one tape cartridge from
the top I/E station slot, and then put the tape cartridge back into the
same slot. To run this test, you must insert a tape into the library’s top
(uppermost) I/E station slot.
You can only perform this test from the Web client, by entering
Diagnostics (see
Performing Library Diagnostics
on page 259).
Web Client
1
Install a scratch tape in the top I/E station slot.
2
If manual cartridge assignment is enabled, assign the scratch tape
to the System partition.
3
Enter Diagnostics (
Tools > Diagnostics
, then click
OK
to take
partitions offline and log out all other users of the same or lower
privileges).
4
Select
Robotics > Robotics Get/Put Test
.
5
Click
Apply
.
6
The test runs. When complete, a “success” or “failure” message
appears.
Resetting Factory Defaults
Resetting factory defaults restores the library’s default configuration
(see
Default Configuration
on page 42).
•
Resetting factory defaults clears:
most of the library’s
configurable items, such as partitions, user accounts, import/export
(I/E) station slots, cleaning slots, and so on. It also clears all
diagnostic tickets and log information, and deletes user-provided
tape drive firmware used for autoleveling.
•
Resetting factory defaults does NOT clear:
date and time,
network configuration, or license key settings, nor does it change
the library firmware version.
Summary of Contents for Scalar i40
Page 16: ...Figures xvi Quantum Scalar i40 and Scalar i80 User s Guide...
Page 18: ...Tables xviii Quantum Scalar i40 and Scalar i80 User s Guide...
Page 22: ...Preface xxii Quantum Scalar i40 and Scalar i80 User s Guide...
Page 26: ...Preface xxvi Quantum Scalar i40 and Scalar i80 User s Guide...
Page 328: ...Index 302 Quantum Scalar i40 and Scalar i80 User s Guide...