Chapter 9: Troubleshooting
Troubleshooting Library “Not Ready” Messages
Quantum Scalar i40 and Scalar i80 User’s Guide
249
The library “not ready” messages include the following, with possible
solutions listed:
Message
Resolution
Library is not ready
The library is initializing and becoming
ready. Wait for the library to finish
initialization.
Library is becoming ready
Wait for the library to finish
initialization.
Library is not initialized
Most likely a problem with the robot.
Try the following:
• Check the diagnostic ticket and
follow the resolution steps listed (see
About Diagnostic Tickets
on
page 244).
• Power cycle the library to clear the
error. If that fails, contact Quantum
Support.
Library needs manual
attention
Most likely a problem with the robot or
other component. Try the following:
• Check the diagnostic ticket and
follow the resolution steps listed (see
About Diagnostic Tickets
on
page 244).
• Power cycle the library to clear the
error. If that fails, contact Quantum
Support.
Note:
You may not see the “not ready” message in the Web client
until the browser refreshes. Similarly, even if the problem has
been resolved, the “not ready” message will not disappear
from the Web client until the browser refreshes.
Summary of Contents for Scalar i40
Page 16: ...Figures xvi Quantum Scalar i40 and Scalar i80 User s Guide...
Page 18: ...Tables xviii Quantum Scalar i40 and Scalar i80 User s Guide...
Page 22: ...Preface xxii Quantum Scalar i40 and Scalar i80 User s Guide...
Page 26: ...Preface xxvi Quantum Scalar i40 and Scalar i80 User s Guide...
Page 328: ...Index 302 Quantum Scalar i40 and Scalar i80 User s Guide...