Chapter 8: Installing, Removing, and Replacing Components
Installing the Library in a Desktop Kit
192
Quantum Scalar i40 and Scalar i80 User’s Guide
Space Requirements
See the following:
•
Physical Specifications
on page 269 and
•
Air Clearance Requirements
on page 271
Procedure
WARNING:
Two people are required to safely lift the library.
1
If your library is currently installed in a rack, remove the magazines
and tape drives, and then remove the library from the rack. See
Removing the Library From a Rack
on page 188.
2
Set the library on the desk or table in your chosen location.
3
Remove all the magazines from the library (if you have not already
done so), as follows:
a
Insert the magazine lock override tool into the access hole in the
bottom of the magazine bezel (see
Figure 42
).
b
Use the tool to depress the release latch while gently pulling
outward on the magazine bezel handle. If the magazine is on
the right side, it will only slide out as far as the I/E station. To
release the magazine fully:
• On the Scalar i40 and the bottom right magazine of the
Scalar i80, reach under the open magazine and insert the
tool directly into the access hole in the library chassis to
depress the release latch, while pulling out on the magazine
bezel handle.
• On the top right magazine of the Scalar i80, reach under the
open magazine and press the release latch directly with
your finger, while pulling out on the magazine bezel handle.
Summary of Contents for Scalar i40
Page 16: ...Figures xvi Quantum Scalar i40 and Scalar i80 User s Guide...
Page 18: ...Tables xviii Quantum Scalar i40 and Scalar i80 User s Guide...
Page 22: ...Preface xxii Quantum Scalar i40 and Scalar i80 User s Guide...
Page 26: ...Preface xxvi Quantum Scalar i40 and Scalar i80 User s Guide...
Page 328: ...Index 302 Quantum Scalar i40 and Scalar i80 User s Guide...