Chapter 8: Installing, Removing, and Replacing Components
Removing and Replacing the Front Bezel
198
Quantum Scalar i40 and Scalar i80 User’s Guide
Removing and Replacing the Front Bezel
The procedure is the same for the Scalar
®
i40 and the Scalar i80. The
pictures show the Scalar i40.
You may perform this procedure with library power
ON
. If you do, be
careful not to accidentally press the power button and turn the library
off when installing the bezel.
Required Tools
• Phillips #1 screwdriver
Bezel Replacement Kit
Contents
• 1 Bezel
• 4 screws
Bezel Replacement
Procedure
1
Stop all library operations.
2
Open all the magazines in the library a few inches.
a
On the operator panel, select
Actions > Magazine
.
b
Select a magazine and press
Release
.
c
When prompted, pull open the magazine a few inches.
d
Repeat for all magazines in the library.
3
Prepare to gain access to the bezel screws (see
Figure 46
on
page 200 and
Figure 47
on page 201 for locations). The method
depends upon how your library is installed. Follow the instructions
in the table below that correspond to your library installation.
If your library is...
Follow these steps...
Installed in a rack high enough
to access to the bottom bezel
screws
Unscrew all the thumbscrews that secure the library to
the rack (the Scalar i40 has two thumbscrews; the
Scalar i80 has four). See
Figure 47
on page 201.
Summary of Contents for Scalar i40
Page 16: ...Figures xvi Quantum Scalar i40 and Scalar i80 User s Guide...
Page 18: ...Tables xviii Quantum Scalar i40 and Scalar i80 User s Guide...
Page 22: ...Preface xxii Quantum Scalar i40 and Scalar i80 User s Guide...
Page 26: ...Preface xxvi Quantum Scalar i40 and Scalar i80 User s Guide...
Page 328: ...Index 302 Quantum Scalar i40 and Scalar i80 User s Guide...