4–5
Troubleshooting
CHANGE RIBBON
Instruction
Indication
Yes
No
1.
Check for fault message
when using the
RibbonMinder feature.
CHANGE RIBBON
message.
Replace the
ribbon.
—
COOLING
Instruction
Indication
Yes
No
1.
Check for inoperative blower
assembly, air flow sensor, or
MCU PCBA.
COOLING message.
Replace one at a
time, in the
following order,
until the message
disappears:
mechanism driver,
MCU PCBA,
sensor, blower.
—
FONT PROM *
Instruction
Indication
Yes
No
1.
Set power switch to O (OFF).
Wait 5 seconds. Set power
switch to 1 (ON).
FONT PROM *
message.
Step 2.
Return printer to
normal operation.
2.
Press the CLEAR switch.
FONT PROM *
message.
Step 3.
Return printer to
normal operation.
3.
Run a diagnostic self–test
(page 4–14).
FONT PROM *
message.
Replace all font
PROM chips on
the DCU PCBA.
Return printer to
normal operation.