2-27
1
Before Using the Products
2
Preparation
3
Connection
4
Setup
5
Adjustment
6
When in T
rouble
7
Supplement
2
Preparation
2.
System Configuration and Wiring
Wiring Diagram (F-frame, 200 V type)
Note
Related page
The wiring indicated with the broken line shall be provided only when required.
• P.2-28 “Specifications of Motor connector”
Compose the circuit so that the main circuit power will be shut off when an error occurs.
However, if you want to use “immediate stop function” and the main circuit power turns off,
please be aware that you will no longer be able to use “immediate stop function”.
In Case of 3-Phase, F-frame, 200 V type
Power supply 3-phase, 200 V –15 % to 230 V +10 %
Note.1)
Frame
No.
Short bar
(Accessory)
Built-in
regenerative
resistor
Connection of terminal block
In case of using
an external regenerative resistor.
In case of not using
an external regenerative resistor.
F-frame
with
with
• Remove the short bar accessory from
between RB-B.
• Connect an external regenerative resistor
between P-B.
• Shorted between RB-B with an attached
short bar
Built-in thermal protector
of an external
regenerative resistor
(light yellow)
Motor
37
ALM+
L2
L3
L1C
L2C
MC
MCCB
L1
ALM−
X4
Terminal block
36
L
ON
ALM
P
RB
B
N
U
V
W
ALM
OFF
MC
Noise filter
External regenerative resistor
Main power
supply
Control power
supply
Motor
connection
Coil surge suppression units
Insulated
DC12 to 24 V
(±5 %)
+
−
Note.1) Short bar