7. Applied functions
Adjustment
Position compare output function
Outline
A pulse signal can be output from the generic output or the position compare output
when the actual position has passed the position set in the parameter.
Specification
Trigger output
I/F
[Generic output]
6 output (SO1 to 6)
: Photocoupler (Open collector)
[Position compare output]
1 output (OCMP4): Open collector
3 output (OCMP1 to 3): Line driver
Logic
Parameter set (Polarity can be set for each output)
Pulse width
Parameter set 0.1 to 3276.7 ms (in 0.1 ms units)
Delay
compensation
Available
Compare
source
Encoder (comms)
Available
External scale
(comms)
Available
External scale
(A, B phase)
Available
Compare value
Set quantity
8 points
Set range
32-bit with sign
Applicable range
This function is available only when the following conditions are satisfied:
Conditions where position compare output function are valid
Control Mode
・
Either position control or full-closed control
Others
・
Block operation set to valid (Pr6.28≠0)
・
Return to origin operation completed state if in incremental mode.
(In case block operation return to origin invalid setting is set to invalid).
・
All parameters except for the control parameters are set appropriately
and there are nothing to obstruct the normal rotation of the motor.