4-84
Note
Related page
• A parameter is designated as follows:
Pr0.00 Parameter No.
Class
• For parameters which No. have a suffix of “
*
”
, changed contents will be validated when
you turn on the control power.
• P.3-32... “Inputs and outputs on connector X4”
Default: [ ]
4
1. Details of parameter
Setup
[Class 7] Special setting
Pr7.14
Main power turn-off warning detection time
Range
Unit
Default
Related
control mode
0 to 2000
ms
0
P S T F
Sets the time elapsed before the main power turn-off warning is detected when a main
power turn-off state continues.
0 to 9, 2000: Warning detection disabled
10 to 1999: Warning detection enabled (unit shown in ms).
Note) To cause the warning detection to occur earlier than turn-off detection, maintain the
relationship "Pr7.14 < Pr5.09" when this parameter is set.
In addition, when the time set for Pr7.14 is long and the P-N voltage at the main power
converter area is reduced to the specified value or below before the warning is detected,
Err13.0 "Main power insufficient voltage protection" is invoked earlier than the warning.
Pr7.22
Special function enhancement setting 1
Range
Unit
Default
Related
control mode
−32768 to 32767
—
0
P S T F
Sets various function in bit units:
bit
Function
Setup value
bit0-3
Not used
Fixed to 0.
bit4
external scale position information monitor function
setting under semi-closed control
0:Invalid
1:Valid
bit5-15
Not used
Fixed to 0.
*bit 0 is the least significant bit.
*For bit 4 (external scale position information monitor function setting under semi-closed
control”), external scale position information can be monitored regardless of the setting
of this bit, in case of full closed control.
All other parameters will be manufacturers use.Please do not change the default
parameters.