3-33
1
Before Using the Products
2
Preparation
3
Connection
4
Setup
5
Adjustment
6
When in T
rouble
7
Supplement
3
4.
Inputs and outputs on connector X4
Connection
Interface Circuit (Input)
Input Circuit
SI
Connection to sequence input signals
Related
control mode
P
S
T
F
Note
• Connect to contacts of switches and relays, or open collector output transistors.
• When you use contact inputs, use the switches and relays for micro current to avoid contact
failure.
• Make the lower limit voltage of the power supply (12 V to 24 V) as 11.4 V or more in order to
secure the primary current for photocouplers.
12 V to 24 V
7
COM+4.7 k
Ω
SRV-ON etc.
Re ay
7
COM+4.7 k
Ω
12 V to 24 V
SRV-ON etc.
• 10 systems: SI1 to SI10. For assign and function, refer to P.3-40 to P.3-45.
Related page
P.3-54
PI1
Connection to sequence input signals (Pulse train interface)
Related
control mode
P
S
T
F
(1) Line driver I/F (
Permissible max. input frequency of command pulse input signal.
: 500 kpulse/s)
• This signal transmission method has better noise immunity.
We recommend this to secure the signal transmission.
(2) Open collector I/F (Permissible max. input frequency of command pulse input signal.: 200
kpulse/s)
• The method which uses an external control signal power supply (VDC)
• Current regulating resistor (R) corresponding to V
DC
is
required in this case.
• Connect the specified resister as below.
• (R) should be placed close to the driver for effective noise reduction.
(3) Open collector I/F (Permissible max. input frequency of command pulse input signal.: 200
kpulse/s)
• Connecting diagram when a current regulating resistor is not used with 24 V power supply.
(1)
(2)
(3)
*
Keep the length of wiring short (1 m or less).
3 PULS1
4 PULS2
220
Ω
V
DC
R
5 SIGN1
6 SIGN2
220
Ω
R
1 OPC1
4 PULS2
220
Ω
24 V
DC
2 OPC2
6 SIGN2
220
Ω
2.2 k
Ω
2.2 k
Ω
3 PULS1
4 PULS2
220
Ω
5 SIGN1
6 SIGN2
220
Ω
13
13
13
• 1 system: PI1. For function, refer to P.3-38, P.3-39.
Max.input voltage :
DC24 V, Rated current : 10 mA
represents twisted pair.
When using open collector interface, it is
recommended to set Pr0.05 to 2.
V
DC
12 V
24 V
V
DC
–1.5
R+220
≒
10 mA
Specifications
820
Ω
1/2 W
2 k
Ω
1/2 W