(8) Alarm Display
alarm
No.
Alarm
Content
Latched
time
*
1
A0
Overload protection
Load factor is 85 % or more the protection level.
1 s to 10 s or ∞
A1
Over-regeneration
alarm
Regenerative load factor is 85 % or more the
protection level.
10 s or ∞
A2
Battery alarm
Battery voltage is 3.2 V or lower.
Fixed at ∞
A3
Fan alarm
Fan has stopped for 1 sec.
1 s to 10 s or ∞
A4
Encoder communication
alarm
The number of successive encoder communication
errors exceeds the specified value.
1 s to 10 s or ∞
A5
Encoder overheat alarm The encoder detects overheat alarm.
1 s to 10 s or ∞
A6
Oscillation detection
alarm
Oscillation or vibration is detected.
1 s to 10 s or ∞
A7
Lifetime detection alarm Life expectancy of capacitor or fan is short.
Fixed at ∞
A8
External scale error
alarm
The external scale detects the alarm.
1 s to 10 s or ∞
A9
External scale
communication alarm
The number of successive external scale
communication errors exceeds the specified
value.
1 s to 10 s or ∞
AC
Deterioration diagnosis
warning
Load characteristic estimates and torque
command under constant speed has exceeded
the set range.
1 s to 10 s or ∞
C3
Main power off warning
In case that Pr7.14 (Detection time of main power
off warning) is 10 to 1999, the mains power
between L1 and L3 has stopped instantaneously
for more than the time prescribed in Pr7.14.
1 s to 10 s or
∞
*
1 Alarms can be cleared by using the alarm clear. Because the all existing alarms are kept cleared while the alarm
clear input (A-CLR) is kept ON, be sure to turn it OFF during normal operation. Either 1 s to 10 s or ∞ can be
selected by using user parameter.
Exception: Battery alarm is fixed at ∞ because it is latched by the encoder.
Because the end of life alarm means that the life expectancy cannot be extended, the alarm is set at ∞.
......No alarm occurred
......High priority alarm
Alarm number
• To display the alarm occurrence condition, press or button.