5-35
1
Before Using the Products
2
Preparation
3
Connection
4
Setup
5
Adjustment
6
When in T
rouble
7
Supplement
Setup of Gain Switching Condition
• Positing control mode, Full-closed control mode (
: Corresponding parameter is valid, – : invalid)
Setup of gain switching condition
Setup parameters at position control, full-closed control
Delay time
*
1
Level
Hysteresis
*
2
Pr1.15
Switching condition to
2nd gain
Fig.
Pr1.16
Pr1.17
Pr1.18
0
Fixed to 1st gain
–
–
–
1
Fixed to 2nd gain
–
–
–
2
Gain switching input
–
–
–
3
Torque command
A
[%]
[%]
4
Invalid
(Fixed to 1st gain)
–
–
–
5
Speed command
C
[r/min]
[r/min]
6
Position deviation
D
*
3
[pulse]
*
3
[pulse]
7
Position command exists.
E
–
–
8
Not in positioning complete
F
–
–
9
Speed
C
[r/min]
[r/min]
10
Command velocity
G
[r/min]
*
5
[r/min]
*
5
• Velocity control mode
Setup of gain switching condition
Setup parameters at velocity control mode
Delay time
*
1
Level
Hysteresis
*
2
Pr1.20
Switching condition to
2nd gain
Fig.
Pr1.16, 1.21
Pr1.17, 1.22
Pr1.18, 1.23
0
Fixed to 1st gain
–
–
–
1
Fixed to 2nd gain
–
–
–
2
Gain switching input
–
–
–
3
Torque command
A
[%]
[%]
4
Variation of speed command is
large.
B
–
*
4
[10(r/min)/s]
*
4
[10(r/min)/s]
5
Speed command
C
[r/min]
[r/min]
• Torque control mode
Setup of gain switching condition
Setup parameters at torque control mode
Delay time
*
1
Level
Hysteresis
*
2
Pr1.24
Switching condition to
2nd gain
Fig.
Pr1.16, 1.25
Pr1.17, 1.26
Pr1.18, 1.27
0
Fixed to 1st gain
–
–
–
1
Fixed to 2nd gain
–
–
–
2
Gain switching input,
GAIN ON
–
–
–
3
Variation of torque command is
large.
A
[%]
[%]
4. Manual Gain Tuning (Basic)
Gain Switching Function
Hysteresis
(Pr1.18, 1.23, 1.27)
Level
Pr1.17
Pr1.22
(
Pr1.26
)
0
H
L
*
1 Delay time (Pr1.16, 1.12 and 1.25) will be valid only when returning from 2nd to 1st
gain.
*
2 Hysteresis (Pr1.18, 1.23 and 1.27) is defined as the fig. below shows.
*
3 Designate with either the encoder resolution or the
external
scale resolution depend-
ing on the control mode.
*
4 When you make it a condition that
there is speed variation of 10 r/min in
1s, set up the value to 1.
*
5 When Pr1.15=10, the meanings of
delay time, level and hysteresis are
different from the normal. (refer to Fig. G)
Buy: www.ValinOnline.com | Phone 844-385-3099 | Email: [email protected]