Default: [ ]
Pr6.61
1st resonance frequency
Range
Unit
Default
Related
control mode
0 to 3000
0.1 Hz
0
P
Sets the resonance frequency for the load of model 1 type vibration control filter.
Pr6.62
1st resonance damping ratio
Range
Unit
Default
Related
control mode
0 to 1000
—
0
P
Sets the resonance damping ratio of the 1st model type resonance oppression notch filter.
Pr6.63
1st antiresonance frequency
Range
Unit
Default
Related
control mode
0 to 3000
0.1Hz
0
P
Sets the antiresonance frequency of the 1st model type resonance oppression notch filter.
Pr6.64
1st antiresonance damping ratio
Range
Unit
Default
Related
control mode
0 to 1000
—
0
P
Sets the antiresonance damping ratio of the 1st model type resonance oppression notch
filter.
Pr6.65
1st response frequency
Range
Unit
Default
Related
control mode
0 to 3000
0.1Hz
0
P
Sets the response frequency of the 1st model type resonance oppression notch filter.
Pr6.66
2nd resonance frequency
Range
Unit
Default
Related
control mode
0 to 3000
0.1Hz
0
P
Sets the resonance frequency of the 2nd model type resonance oppression notch filter.
Pr6.67
2nd resonance damping ratio
Range
Unit
Default
Related
control mode
0 to 1000
—
0
P
Sets the resonance damping ratio of the 2nd model type resonance oppression notch filter.
Pr6.68
2nd antiresonance frequency
Range
Unit
Default
Related
control mode
0 to 3000
0.1Hz
0
P
Sets the antiresonance frequency of the 2nd model type resonance oppression notch filter.
Pr6.69
2nd antiresonance damping ratio
Range
Unit
Default
Related
control mode
0 to 1000
—
0
P
Sets the antiresonance damping ratio of the 2nd model type resonance oppression notch
filter.