2-25
1
Before Using the Products
2
Preparation
3
Connection
4
Setup
5
Adjustment
6
When in T
rouble
7
Supplement
2.
System Configuration and Wiring
Overall Wiring (F-frame, 200 V type)
• P.2-26 “
Wiring of the Main Circuit
(F-frame, 200 V type)” • P.2-28 “Specifications of Motor connector”
Related page
P.2-26
Short bar (RB-B)
Ground
terminal
Charge lamp
(Red LED)
*
1
Junction cable
for brake
DC Power supply for brake
DC24 V
(to be supplied by customer)
Junction cable for motor
Junction cable
for encoder
: High voltage
U-phase(red)
V-phase(white)
W-phase(black)
*
1 Do not make displacement, wiring or inspection while the LED is lit - cause of electric shock.
PC (to be supplied by customer)
Setup support software
“PANATERM”
Please download
from our web site.
• Connection to PC (PANATERM)
• Connection to RS232, RS485
or host controller
• Connection to Safety controller
• Connection to
encoder
• Connection to
feedback scale
• Connection to host controller
Wiring to Connector, X6
P.
2-38
Wiring to Connector, X5
P.2-36
Wiring to Connector, X4
P.2-35
Wiring to Connector, X3
P.2-34
Wiring to Connector, X2
P.2-32
Wiring to Connector, X1
P.2-32
Connection to motor driving
phase and ground
*
These colors are
used for optional
cable.
• X1 to X6 are used for the secondary
circuit. To connect these terminals to
the primary power supply (particularly,
24 VDC power supply for brake),
insulation is required.
Do not connect these terminals to the
same power supply.
Remarks
Ground
(earth)
Buy: www.ValinOnline.com | Phone 844-385-3099 | Email: [email protected]