5-73
1
Before Using the Products
2
Preparation
3
Connection
4
Setup
5
Adjustment
6
When in T
rouble
7
Supplement
Related parameters
Class No.
Title
Function
4
44
Position compare
output pulse width
setting
Sets pulse width of position compare output
No pulse output when 0 (zero)
4
45
Position compare
output polarity
select
Polarity of position compare output can be set by bit for
each output terminal.
・
Set bits
bit0
:
SO1 or OCMP1
bit1
:
SO2 or OCMP2
bit2
:
SO3 or OCMP3
bit3
:
SO4 or OCMP4
bit4
:
SO5 bit5
:
SO6
・
Set value
0
:
Sets output photocoupler to ON for SO1 to 6, during
pulse output and to L level for OCMP 1 to 4.
1
:
Sets output photocoupler to OFF for SO1 to 6,
during pulse output and to H level for OCMP 1 to 4.
Basically to be used set to 0.
4
47
Pulse output select
Selects signal to be output from pulse output/position
compare output terminal:
Set
value
Connector pin
No.21/22
Connector pin
No.48/49
Connector pin
No.23/24
Connector pin
No.19
0
OA
OB
OZ
CZ
1
OCMP1
OCMP2
OZ
CZ
2
OA
OB
OCMP3
OCMP3
3
OCMP1
OCMP2
OCMP3
OCMP3
4
OA
OB
OZ
OCMP4
5
OCMP1
OCMP2
OZ
OCMP4
6
OA
OB
OCMP3
OCMP4
7
OCMP1
OCMP2
OCMP3
OCMP4
*OA, OB, OZ, and CZ are pulse output signals and
OCMP1, OCMP2, OCMP3, and OCMP4 are position
compare output.
4
48
Position compare
output polarity select 1
Sets position compare 1 comparison value
4
49
Position compare
output polarity select 2
Sets position compare 2 comparison value
4
50
Position compare
output polarity select 3
Sets position compare 3 comparison value
4
51
Position compare
output polarity select 4
Sets position compare 4 comparison value
4
52
Position compare
output polarity select 5
Sets position compare 5 comparison value
4
53
Position compare
output polarity select 6
Sets position compare 6 comparison value
4
54
Position compare
output polarity select 7
Sets position compare 7 comparison value
7. Applied functions