2-102
• Procedure for Trial Run
Caution
Note
•
Before starting the trial run, set the gain-related parameters to appropriate values to avoid
problems such as oscillation. If the load is removed, be sure to set Pr0.04 “Inertia Ratio” to 0.
•
During the trial run, use the velocity control mode. Various settings including parameters
should assure safe and positive operation under appropriate velocity control.
•
If SRV-ON becomes valid during trial run, the display changes to
which is nor-
mal run through external command.
•
After finished trial running, return to SELECTION display, referring to structure of each mode
(P.2-76).
Keep pressing (approx. 5 sec)
to shift the decimal point toward
left as the left fig. shows.
• Then keep pressing until the display of LED changes to
.
Not a servo-ready status.
(Shuts off the main when
error occurs.)
• After the Servo-ON of preparation step 2 for trial run,
the motor runs at the preset speed with Pr6.04 (JPG speed)
to Positive direction direction by pressing Negative
direction by pressing .
Preparation
step 1
Preparation
step 2
Not a Servo-Ready.
Or SRV-ON signal is
not entered.
• Press to call for
EXECUTION display.
(SET button)
SELECTION display
EXECUTION display
“ ” increases while keep
pressing (for approx. 5sec)
as the left fig. shows.
• Keep pressing until the display changes to
when you execute Motor trial run.
14. How to Use the Front Panel
Auxiliary Function Mode (EXECUTION display)
Buy: www.ValinOnline.com | Phone 844-385-3099 | Email: [email protected]