1-27
1
Before Using the Products
2
Preparation
3
Connection
4
Setup
5
Adjustment
6
When in T
rouble
7
Supplement
1
Before Using
the Products
6. Permissible Load at Output Shaft
Motor
L
L/2
P
A
M
B
Radial load (P) direction
Thrust load (A and B) direction
Unit : N (1 kgf=9.8 N)
Motor
series
Motor output
At assembly
During running
Radial thrust
Thrust load
Radial thrust
Thrust load A
and
B-direction
A-direction B-direction
MSMF
50 W, 100 W
147
88
117.6
68.6
58.8
200 W, 400 W
392
147
196
245
98
750 W,
1.0 kW(
□
80)
686
294
392
392
147
1.0 kW(
□
100)
to 3.0 kW
980
588
686
490
196
4.0 kW, 5.0 kW
784
343
MQMF
100 W
147
88
117.6
68.6
58.8
200 W, 400 W
392
147
196
245
98
MDMF
1.0 kW to 2.0 kW
980
588
686
490
196
3.0 kW
784
343
4.0 kW,5.0 kW
1666
784
980
MGMF
850 W to 1.8 kW
980
588
686
686
196
2.4 kW
1666
784
980
1176
490
2.9 kW
4.4 kW
1470
MHMF
50 W
147
88
117.6
68.6
49
100 W
58.8
200 W, 400 W
392
147
196
245
98
750 W,1.0 kW(
□
80)
686
294
392
392
147
1.0 kW(
□
130),
1.5kW
980
588
686
490
196
2.0 kW to 5.0 kW
1666
784
980
784
343
Note
When the load point varies, calculate the permissible radial load, P (N) from the distance
of the load point, L (mm) from the mounting flange based on the formula of the right ta
-
ble, and make it smaller than the calculated result.
Buy: www.ValinOnline.com | Phone 844-385-3099 | Email: [email protected]