7-60
7
5. Motor Characteristics (
S-T
Characteristics
)
Supplement
MSMF series
(400 W)
•
Note that the motor characteristics may vary due to the existence of oil seal or brake.
Motor model
Unit
MSMF041L1
□□
MSMF042L1
□□
Brake
without
with
without
with
Oil seal
without/with
without/with
Output rating
W
400
400
Matched drive
MCDL
□
31
□□
MBDL
□
25
□□
Power supply of drive
V(AC)
100
200
Rated torque
N·m
1.27
1.27
Continuous stall torque
N·m
1.27
1.27
Max.instantaneous speed
N·m
3.82
3.82
Rated curren
A
(
rms
)
4.6
2.4
Max.instantaneous current
A
(
o-p
)
19.5
10.2
Rated rotational speed
r/min
3000
3000
Max.rotational speed
r/min
6000
6000
Rotor inertia
×10
-4
k
g
·m
2
0.27
0.30
0.27
0.30
MSMF series
(400 W)
Without oil seal
With oil seal
*
These are subject to change. Contact us when you use these values for your machine design.
●
MSMF041L1
□□
Input voltage to driver: AC200 V
(Dotted line represents torque at 10 % less voltage.)
●
MSMF041L1
□□
Input voltage to driver: AC200 V
(Dotted line represents torque at 10 % less voltage.)
●
MSMF042L1
□□
Input voltage to driver: AC200 V
(Dotted line represents torque at 10 % less voltage.)
●
MSMF042L1
□□
Input voltage to driver: AC200 V
(Dotted line represents torque at 10 % less voltage.)
50
90
100
10
0
20
30
40
ratio vs. rated torque
[%]
*
Continuous torque vs. ambient temp.
ambient temp. [°C]
orque
[N·m]
speed [r/min]
50
100
75
10
0
20
30
40
ratio vs. rated torque
[%]
*
Continuous torque vs. ambient temp.
ambient temp. [°C]
ambient temp. [°C]
*
Continuous torque vs. ambient temp.
ambient temp. [°C]
Peak running range
(3100)
(2600)
0
3000
6000
Continuous running range
2.0
4.0
orque
[N·m]
speed [r/min]
Peak running range
(3100)(3600)
0
3000
6000
Continuous running range
2.0
4.0
speed [r/min]
·have brake and no brake
have same characteristics。
·have brake and no brake
have same characterist cs。
·have brake and no brake
have same characteristics。
·have brake and no brake
have same characteristics。
50
90
100
10
0
20
30
40
ratio vs. rated torque
[%]
orque
[N·m]
speed [r/min]
orque
[N·m]
Peak running range
(3100)
(2600)
0
3000
6000
Continuous running range
2.0
4.0
Peak running range
(3100)(3600)
0
3000
6000
Continuous running range
2.0
4.0
50
100
75
10
0
20
30
40
ratio vs. rated torque
[%]
*
Continuous torque vs. ambient temp.
(0.32)
(0.64)
(0.64)
(0.32)
(1.7)
(1.6)
(1.6)
(1.7)
Buy: www.ValinOnline.com | Phone 844-385-3099 | Email: [email protected]