4-52
Default: [ ]
Pr5.00
2nd numerator of electronic gear
Range
Unit
Default
Related
control mode
0 to 2
30
—
0
P
F
Pr5.01
3rd numerator of electronic gear
Range
Unit
Default
Related
control mode
0 to 2
30
—
0
P
F
Pr5.02
4th numerator of electronic gear
Range
Unit
Default
Related
control mode
0 to 2
30
—
0
P
F
Set the 2nd to 4th numerator of division/multiplication operation made according to the
command pulse input.
This setup is enabled when Pr0.08 command pulse counts per one motor revolution = 0 or
full closed controlling.
When the setting value is 0 for positioning controlling, encoder resolution is set as a
numerator.
When the setting value is 0 for full closed controlling, both numerator and denominator are set to 1.
Pr5.03
*
Denominator of pulse output division
Range
Unit
Default
Related
control mode
0 to 8388608
—
0
P S T F
For details, refer to P.4-11.
Pr5.04
*
Over-travel inhibit input setup
Range
Unit
Default
Related
control mode
0 to 2
—
1
P S T F
Set up the operation of the run-inhibition (POT, NOT) inputs.
Setup value
Operation
0
POT
Inhibit positive direction travel
NOT Inhibit negative direction travel
[1]
Disable POT, NOT
2
POT or NOT input activates Err38.0 Run-inhibition input protection.
4
1. Details of parameter
Setup