2-83
1
Before Using the Products
2
Preparation
3
Connection
4
Setup
5
Adjustment
6
When in T
rouble
7
Supplement
(5) Display of I/O Signal Status
Displays the control input and output signal to be connected to connector X4.
Use this function to check if the wiring is correct or not.
14. How to Use the Front Panel
Monitor Mode (EXECUTION display)
Note
For detail of input/output signal, refer to P.3-33 “Inputs and outputs on connector X4”
For detail of Error Code, refer to P.6-2 “Protective Function”.
• Shift the flashing decimal point with .
.....Input signal
.....Output signal
Pin No.
.....Active
*
1
.....Inactive
*
1
*
1 When input signal
Active : Input signal photocoupler is ON.
Inactive : Input signal photocoupler is OFF.
When output signal Active : Output signal transistor is ON.
Inactive : Output signal transistor is OFF.
• Select the Pin No. to be monitored by pressing .
• Select In or Out by pressing or button.
(Right side of decimal point : Pin No. selection)
(Left side of decimal point : Input/Output Pin No. selection)
(Lowest place Pin No.
of output signal)
(Highest place Pin No.
of input signal)
Buy: www.ValinOnline.com | Phone 844-385-3099 | Email: [email protected]