Parallel I/O connection
164
ZW User's Manual
Operating Mode Switching
In FUN mode, there is no binary output. Immediately after the mode is switched to RUN mode, the clamp value is
output until the measured value is applied.
Explanation of operations
(1) After the mode is switched from RUN to FUN mode, the BUSY output and ENABLE output are turned OFF.
The judgment outputs all go OFF and the binary output is output clamped.
(2) The response time of analog output after the BUSY output is turned ON, the analog output is output
clamped.
(3) After the mode is switched from FUN mode to RUN mode, the BUSY output is turned OFF.
(4) Measurement is restarted and the ENABLE signal is turned ON, then the measurement results are output.
Item
Min.
Max.
T3
Response time of analog output
0.1 ms
T9
Measurement start response time
3 × T0
Depends on the set conditions
(1)
(3)
T3
RU
N
FU
N
RU
N
(2)
(4)
T9
O
N
OFF
O
N
OFF
O
N
OFF
J
u
dgment o
u
tp
u
t
(HIGH/PASS/LO
W
)
Binary o
u
tp
u
t
GATE o
u
tp
u
t
Analog o
u
tp
u
t
BUSY o
u
tp
u
t
E
N
ABLE o
u
tp
u
t
MODE
All OFF
CLAMP
CLAMP
Important
Summary of Contents for ZW-C1*T
Page 70: ...Operating with Sensor Controller 68 ZW User s Manual MEMO ...
Page 116: ...Setting the System 114 ZW User s Manual MEMO ...
Page 134: ...Controll input signal with PC tool 132 ZW User s Manual MEMO ...
Page 209: ...8 Troubleshooting Troubleshooting 8 1 Error Messages 208 8 2 Troubleshooting 210 ...
Page 319: ...Index ZW User s Manual 317 Index 11 ...
Page 321: ......