![background image](http://html.mh-extra.com/html/omron/zw-c1-t/zw-c1-t_user-manual_1633390173.webp)
No-protocol Connection
ZW User's Manual
171
6
Commun
ication
s with Exte
rnal De
vi
ces
Initial Settings for No-protocol Communications
You must set the communications method, destination IP address, and I/O port number of the destination
external device to perform no-protocol communications.
Explorer pane
: [Device group] | Sensor name | [System] | [System data] (Double-click)
Edit Pane
: [Ethernet communication settings] icon (
) |
[No-Protocol data communication setting]
If set Communication type to TCP client, please start a ZW after make sure the external device to be TCP
server is ready to communicate. In addition, the communication is interrupted for reasons such as the ethernet
cable is disconnected, please restart the ZW If you can not reconnect.
Item
Description
Setting range
Communication type
Select the communications method.
• OFF
• TCP server
• TCP client
• UDP
(Default: TCP server)
Port No. In
Sets the ZW port number when the UDP or TCP server is
selected.
0 to 65,535
(Default: 9601)
• The following port number is reserved
and cannot be used: 9600
IP address
Set the IP address of the external device at the connection
destination when the UDP or TCP client is selected.
Set it in the form a.b.c.d.
a: 1 to 223, b: 0 to 255,
c: 0 to 255, d: to 254
(Default: 192.168.250.100)
Port No. Out
Set the I/O port number of the external device at the
connection destination when the UDP or TCP client is
selected.
Set the value to between 0 and 65,535.
0 to 65,535
Default: 9,600
(Default: 9,601)
If you connect an external OMRON CS/CJ-
series PLC to Ethernet, the following default IP
address is assigned to the PLC.
• IP address: 192.168.250.node_address
Note
Important
Summary of Contents for ZW-C1*T
Page 70: ...Operating with Sensor Controller 68 ZW User s Manual MEMO ...
Page 116: ...Setting the System 114 ZW User s Manual MEMO ...
Page 134: ...Controll input signal with PC tool 132 ZW User s Manual MEMO ...
Page 209: ...8 Troubleshooting Troubleshooting 8 1 Error Messages 208 8 2 Troubleshooting 210 ...
Page 319: ...Index ZW User s Manual 317 Index 11 ...