![background image](http://html.mh-extra.com/html/omron/zw-c1-t/zw-c1-t_user-manual_1633390102.webp)
Setting the Output Conditions
100
ZW User's Manual
Setting a Trigger Delay
Set this to ignore measure values following TIMING input to avoid the influence of bounding or mechanical
vibration when a device is started up.
The delay time (the delay between timing input and the start of sampling) and the sampling time can be set.
Explorer pane
: [Bank] | [(Bank Data Name)] (double click)
Edit pane
: [Task Settings] icon (
)
Task Settings window : [Hold]
Item
Setting item
Setting value
Description
Trigger delay
Trigger delay mode
OFF (default value)/ON
Turns the trigger delay ON/OFF.
Delay time
1 (default value) to 5,000
[ms]
Set the time from TIMING input ON up to start of sampling.
Sampling time
1 to 5,000 [ms]
(default value: 100ms)
Set to period during which sampling is to be performed.
1
Set the hold mode and trigger.
2
Select ON/OFF from [Trigger delay] - [Trigger
delay mode].
3
Enter [Delay time] and [Sampling time].
Set so that the "delay time + sampling time" is
shorter than the TIMING input interval. When the
TIMING input turns ON again before the "delay
time + sampling time" elapses, the TIMING input
that is input later is ignored and is not reflected in
sampling.
The trigger delay can also be set by the operating keys on the Sensor Controller.
ON
OFF
Measured values in this time period
is included in the sampling.
Delay time
Sampling time
TIMING input
Sampling period
Measured value
Important
Note
Summary of Contents for ZW-C1*T
Page 70: ...Operating with Sensor Controller 68 ZW User s Manual MEMO ...
Page 116: ...Setting the System 114 ZW User s Manual MEMO ...
Page 134: ...Controll input signal with PC tool 132 ZW User s Manual MEMO ...
Page 209: ...8 Troubleshooting Troubleshooting 8 1 Error Messages 208 8 2 Troubleshooting 210 ...
Page 319: ...Index ZW User s Manual 317 Index 11 ...
Page 321: ......