Wiring
ZW User's Manual
2
Install
a
tion an
d
C
onn
ecti
ons
45
Parallel
input
BINARY_SEL input
This selects which task's data is output as binary.
Specify the task number in combinations of BINARY_SEL1 and 2.
It is only enabled in RUN mode.
BANK_SEL input
This is used for switching banks.
Specify the bank number in combinations of BANK_SEL1, 2 and 3.
However, if the bank mode is set to "JUDGEMENT", the bank cannot be switched at the
external signal input because the number of banks increases to 32.
LOGGING input
This is used to start and end internal logging.
Class
Name
Description
Task Number BINARY_SEL1
BINARY_SEL2
TASK1
OFF
OFF
TASK2
ON
OFF
TASK3
OFF
ON
TASK4
ON
ON
Bank Number BANK_SEL1
BANK_SEL2
BANK_SEL3
BANK1
OFF
OFF
OFF
BANK2
ON
OFF
OFF
BANK3
OFF
ON
OFF
BANK4
ON
ON
OFF
BANK5
OFF
OFF
ON
BANK6
ON
OFF
ON
BANK7
OFF
ON
ON
BANK8
ON
ON
ON