![background image](http://html.mh-extra.com/html/omron/zw-c1-t/zw-c1-t_user-manual_1633390298.webp)
Specifications and External Dimensions
296
ZW User's Manual
Status indicators
Note: Do not obtain data during start-up. The RS-232C output is indeterminate at this time.
Mode
Status
Display
Output
Input
RS-232C/
Ethernet
11-segment
display
ANALOG
Output
Judgment
output
(HIGH/
PASS/LOW)
Binary out-
put
LED OFF
Zero
reset
RUN
Normal measurement
Measureme
nt result
Output
according to
measureme
nt result
Judgment
result
Output
according to
the mode
(Measureme
nt result/
Judgment
result)
Enabled
Enabled
Enabled
Measurement
error
KEEP
Previous
value
CLAMP
"------"
Output at
clamp level
Output OFF
Output of
the
measured
value:
clamp level
Judgment
output:
Output OFF
Disabled
Measured value not
applied
LED OFF
FUN
Display
according to
menu
Disabled
System
error
"SYS.ERR"
blinks
Voltage:
0 V output
Current:
12 mA
output
Disabled
Enabled
Commands
are
accepted
but not
executed.
When
starting
"INIT"
Output at
clamp level
(approx. -
10.8 V)
Output OFF
Invalid
(Note)
Summary of Contents for ZW-C1*T
Page 70: ...Operating with Sensor Controller 68 ZW User s Manual MEMO ...
Page 116: ...Setting the System 114 ZW User s Manual MEMO ...
Page 134: ...Controll input signal with PC tool 132 ZW User s Manual MEMO ...
Page 209: ...8 Troubleshooting Troubleshooting 8 1 Error Messages 208 8 2 Troubleshooting 210 ...
Page 319: ...Index ZW User s Manual 317 Index 11 ...
Page 321: ......