![background image](http://html.mh-extra.com/html/omron/zw-c1-t/zw-c1-t_user-manual_1633390164.webp)
Parallel I/O connection
162
ZW User's Manual
LED OFF
Explanation of operations
(1) The LED OFF input is turned ON.
(2) After the LED OFF input is turned ON, the LEDs are turned OFF.
(3) After the LEDs are turned OFF, the ENABLE output is turned OFF.
(4) The LED OFF input is turned OFF.
(5) After the LED OFF input is turned OFF, the LEDs are turned ON.
(6) After the LEDs are lit up, measurement is restarted and the ENABLE output is turned ON.
Item
Min.
Max.
T9
Measurement start response time
3 × T0
Depends on the set conditions
T10
LED OFF input minimum time
100
s
T11
Time of receiving LED OFF input
100
s
T12
ENABLE response time after LEDs are turned OFF
2×T0
(1)
(2)
T11
T12
(3)
(4)
T11
(5)
(6)
T9
T10
O
N
OFF
O
N
OFF
LED OFF inp
u
t
Meas
u
rement
E
N
ABLE o
u
tp
u
t
Clamp
Meas
u
rement
Meas
u
rement
T
u
rn O
N
T
u
rn OFF
T
u
rn O
N
LED
Summary of Contents for ZW-C1*T