Setting Measurement Items
80
ZW User's Manual
Explorer pane
: [Bank] | [(Bank Data Name)] (double click)
Edit pane
: [Task Settings] icon (
)
Task Settings window : [Measurement mode] - [Height]
[Height] and [Edge1] are preset to TASK1 as the measurement item and measurement surface, respectively. To
measure the height in TASK2 to TASK4, set Edge1 first.
Item
Setting item
Setting value
Description
Height settings
Measurement
area
Area 1 (default value)/Area 2
The area targeted for measurement can be switched.
Measurement
surface
Edge1/Edge2/Edge3/Edge4/
peak (default value)
The measurement surface targeted for measurement can
be switched.
The peak is the surface of all measurement surfaces having
the highest received light amount.
1
Select the measurement area targeted for
measurement from [Measurement area].
2
Select the measurement surface targeted for
measurement from [Measurement surface].
Height measurement can also be set by the operating keys on the Sensor Controller.
Important
Note