Settings for Judgment Output
The following describes the settings for outputting the judgment results from the judgment output of the 20-pole
terminal block.
Assigning judgment output
Set the task for which to output the judgment results.
The judgment results for the selected task are output from the following output terminals of the 20-pole terminal
block.
HIGH1/PASS1/LOW1
Explorer pane
: [Bank] | [(Bank Data Name)] (double click)
Edit pane
: [I/O Settings] icon (
)
I/O Setting Screen
: [Judgment]
Item
Setting item
Setting value
Description
Judgment
Output object
TASK1/TASK2/TASK3/TASK4
Select the task for which to output the judgment result.
1
Set the operating mode to the FUN mode.
3-3 Switching operation modes p.57
2
Select the task from [Output object].
Judgment output can also be assigned with key operations on the Sensor Controller.
Assigning judgment output p.271