![background image](http://html.mh-extra.com/html/omron/zw-c1-t/zw-c1-t_user-manual_1633390302.webp)
Specifications and External Dimensions
300
ZW User's Manual
Connection adapter (for connecting fiber cable)
ZW-XFC
The connection adapter (ZW-XFC) comes packed together with the extension fiber cable (ZW-XF
@
R), but the
connection adapter alone can be purchased for maintenance.
Fiber connector cleaner
ZW-XCL
This cleaner can be used only for the following locations:
• Grooves on the fiber connector of the Sensor Controller (C1
@
T)
• Grooves on the connection adapter (ZW-XFC) supplied with the extension fiber cable (ZW-XF
@
R)
Take note that this cleaner must not be used to clean the tips of fiber cables.
For cleaning of the tips of fiber cables, refer to "Connecting Fiber Cable" p.34.
Item
Specifications
Applicable item
• Grooves on the fiber connector of the Sensor Controller (ZW-C1
@
T)
• Grooves on the connection adapter (ZW-XFC) supplied with the extension fiber cable (ZW-
XF
@
R)
Packed quantity
10 pcs/set
Number of times
cleanable
Once
External size
Length 180 mm,
2.4 mm
Operating ambient
temperature range
5 to 35
C
Operating ambient
humidity range
40 to 80%
Storage ambient
temperature range
5 to 35
C
Storage ambient humidity
range
40 to 80%
Material
Nylon plastic, polyolefin plastic, polyester
Weight
20 g
Accessories
Note on use
φ
9.
8
4.5
6
15
(Unit: mm)
(Unit: mm)
151±0.1
φ
2.4±0.05
29±0.1
Summary of Contents for ZW-C1*T
Page 70: ...Operating with Sensor Controller 68 ZW User s Manual MEMO ...
Page 116: ...Setting the System 114 ZW User s Manual MEMO ...
Page 134: ...Controll input signal with PC tool 132 ZW User s Manual MEMO ...
Page 209: ...8 Troubleshooting Troubleshooting 8 1 Error Messages 208 8 2 Troubleshooting 210 ...
Page 319: ...Index ZW User s Manual 317 Index 11 ...
Page 321: ......