Installation of Sensor Controller
Precautions for installation
Install the Sensor Controller in the orientation indicated by the circle mark in the following figure. Do not install
it laying on its side or upside down.
For adequate intake and/or exhaust, keep the Sensor Controller clear by 30 mm or more on its top, and by 10
mm or more from either side.
To secure the Sensor Head and cables connected safely, keep the front of the Sensor Controller clear by 65
mm or more.
If more than one Sensor Controller must be placed in parallel, place them 10 mm or more apart each other,
keep them clear by 30 mm or more on their top and 30 mm or more under them.
Do everything possible to avoid installation in a location with vibration.