Parallel I/O connection
156
ZW User's Manual
Hold (peak/bottom/peak to peak/average)
Explanation of operations
(1) The TIMING input is turned ON.
(2) During the TIMING input minimum time, when the TIMING input is ON, sampling is started and the BUSY
output is turned ON.
(3) After the end of measurement, the judgment results and binary data are output.
(4) After the TIMING input goes OFF, sampling is ended and the judgment results and binary data are output.
The BUSY output is also turned OFF.
(5) After the judgment result and binary data output, the analog output is updated.
(6) After the judgment result and binary data output, the GATE signal is turned ON.
(7) The GATE signal output time after the GATE output is turned ON, the GATE output is turned OFF.
(8) The GATE signal output is turned ON. During the GATE signal output minimum time, if the GATE signal
output is turned ON, the measured value is reset.
(9) The judgment results and binary data are reset.
(10) After the judgment results and binary data are reset, the analog output is reset.
(11) After the judgment results and binary data are reset, the GATE output is turned ON.
(12) The GATE signal output time after the GATE output is turned ON, the GATE signal is turned OFF.(13) The
RESET input is turned OFF.
(13) The RESET input is turned OFF.
Item
Min.
Max.
T3
Response time of analog output
0.1 ms
T4
GATE signal rise time
0.2 ms
T5
GATE signal output time
Setting value
(0.1 to 100.0 ms)
Setting value
(0.1 to 100.0 ms)
T6
TIMING input/RESET input minimum time
3 ms+T0
T7
Response time of input
2 ms+T0
3 ms+T0×2
(2)
(3)
T6
(4) (5)
T7
T6
T3
T4
(6)
T5
(7)
(
8
)
T7
(9)(10)
T7
(11)
(1)
O
N
OFF
O
N
OFF
O
N
OFF
O
N
OFF
T3
T4
T5
(12) (13)
J
u
dgment o
u
tp
u
t
(HIGH/PASS/LO
W
)
Binary o
u
tp
u
t
GATE o
u
tp
u
t
Analog o
u
tp
u
t
B
u
sy o
u
tp
u
t
RESET inp
u
t
(RESET)
TIMI
N
G inp
u
t
(TIMI
N
G)
Summary of Contents for ZW-C1*T
Page 70: ...Operating with Sensor Controller 68 ZW User s Manual MEMO ...
Page 116: ...Setting the System 114 ZW User s Manual MEMO ...
Page 134: ...Controll input signal with PC tool 132 ZW User s Manual MEMO ...
Page 209: ...8 Troubleshooting Troubleshooting 8 1 Error Messages 208 8 2 Troubleshooting 210 ...
Page 319: ...Index ZW User s Manual 317 Index 11 ...
Page 321: ......