Specifications and External Dimensions
ZW User's Manual
295
APPENDICES
10
External inter-
face
52-pole
extension
connector
Bank
Currently
selected
bank output
(BANK_OUT
1 to 3)
Transistor output system
Output voltage: 21.6 to 30 VDC
Load current: 50 mA or less
Residual voltage when turning ON: 1.2 V or less
Leakage voltage when turning OFF: 0.1 mA or less
Bank
Selection
input
(BANK_SEL
1 to 3)
DC input system
Input voltage: 24 VDC ±10% (21.6 to 26.4 VDC)
Input current: 7 mA Type. (24 VDC)
ON voltage/ON current: 19 V/3 mA or more
OFF voltage/OFF current: 5 V/1 mA or less
LOGGING input
DC input system
Input voltage: 24 VDC ±10 % (21.6 to 26.4 VDC)
Input current: 7 mA Typ. (24 VDC)
Voltage/Current when turning ON: 19 V/3 mA or more
Voltage/Current when turning OFF: 5 V/1 mA or less
Main functions Exposure time
Auto/Manual
Measuring cycle
500
s to 10 ms
Material setting
Standard/Mirror/Diffusion surfaces
Measurement Item
Height/Thickness/Calculation
Filtering
Median/Average/Differentiation/High pass/Low pass/Band pass
Outputs
Scaling/Different holds/Zero reset/Logging for a measured value
Display
Measured value/Threshold value/Analog output voltage or current value/
Judgment result/Resolution/Exposure time
Number of configurable banks
Max. 8 banks
Task process
Multi-task (up to 4 tasks per bank)
System
Save/Initialization/Display measurement information/Communication
settings/Sensor Head calibration/Key-lock/TIMING-key input
Rating
Power supply voltage
21.6 to 26.4 VDC (including ripple)
Current consumption
500 mA max.
Insulation resistance
Across all lead wires and Sensor Controller case: 20 M
(by 250 V megger)
Dialectic strength
Across all lead wires and Sensor Controller case: 1,000 VAC, 50/60 Hz, 1
min
Environmental
immunity
Degree of protection
IP20 (IEC60529)
Vibration resistance (destructive)
10 to 55 Hz, 0.35-mm single amplitude, 50 min each in X, Y, and Z directions
Shock resistance (destructive)
150 m/s
2
, 3 times each in six directions (up/down, left/right, forward/
backward)
Ambient temperature
Operation: 0 to +40
C
Storage: -15 to +60
C (with no icing or condensation)
Ambient humidity
Operating and storage: 35 to 85% (with no condensation)
Grounding
D-type grounding (grounding resistance of 100
or less)
Note: For conventional Class D grounding
Material
Chassis: PC
Weight
Approx. 750 g (main unit only)
Accessories
Instruction sheet,
Member
registration sheet
Instruction sheet,
Member
registration sheet
and software for
setting (CD-ROM)
Instruction sheet,
Member
registration sheet
Instruction sheet,
Member
registration sheet
and software for
setting (CD-ROM)
Item
Specifications
ZW-C10T
ZW-C10AT
ZW-C15T
ZW-C15AT
Summary of Contents for ZW-C1*T
Page 70: ...Operating with Sensor Controller 68 ZW User s Manual MEMO ...
Page 116: ...Setting the System 114 ZW User s Manual MEMO ...
Page 134: ...Controll input signal with PC tool 132 ZW User s Manual MEMO ...
Page 209: ...8 Troubleshooting Troubleshooting 8 1 Error Messages 208 8 2 Troubleshooting 210 ...
Page 319: ...Index ZW User s Manual 317 Index 11 ...
Page 321: ......