No-protocol Connection
174
ZW User's Manual
Setting for serial data output after application of measured value
When hold is set, the applied measured data can be output automatically.
Data that can be output
The data to be output is measured values applied at the time that the output cause occurs.
The data to be output is fixed to four tasks, TASK1 to TASK4, and can not be set individually.
Timing for outputting data
When hold (peak, bottom, peak-to-peak, average, sampling) is set, the measured value data is output when a
measured value is applied for even one of the four tasks. For the trigger method, both timing input from the
outside and self-triggering are supported.
Setting the data output destination
Serial data can be output from Ethernet or RS-232C. This section describes the procedure for the setting.
Explorer pane
: [System] (double-click)
Edit pane
: [Data output settings] icon (
)
Item
Setting item
Description
Range
Data output set-
tings
Data output
destination
Sets the interface for serial data output.
OFF (default value)/Ethernet/RS-232C