Setting the Output Conditions
238
ZW User's Manual
Setting the Frequency Filter
Setting the Frequency Filter p.92
As an example, here is an explanation of the procedure for selecting the "LOPASS" setting for the frequency
filter type, and the "1Hz" cut-off frequency filter setting.
Operating procedure
Steps
Key operation
Display
Description
1 to 4
For moving to "FILTER", see steps 1 to 4 in p.236.
5
Select "FRQNCY" as the filter type.
Press the
/
keys to select "FREQ" and press the
key.
6
Select the frequency filter type.
LO.PASS: LOWPASS FILTER
HIPASS: HIGHPASS FILTER
BD.PASS: BANDPASS FILTER
Select "LOPASS" as the frequency filter type.
The current setting value is displayed on the sub-display.
Press
/
key to enter editing mode and the sub-display blinks.
In this example, select "LO.PASS" and press the
key.
7
Set the cut-off frequency.
"CUTOFF" is displayed on the main display and the current setting
value is displayed on the sub-display.
Press
key to enter the editing mode, and the sub-display
blinks.
To edit numerical values, use the
/
/
/
keys.
In this example, input "1", then press the
key.
8
Press the
key for two seconds to enter the RUN mode.