background image

1 - English

Material Safety Data Sheet 

#58387801

Yellow Toner: P/N 44469701 (C330/C530)/

44469719 (C530) 44844509 (C831)

For more information, contact Oki Data at: 2000 Bishops 
Gate Boulevard, Mount Laurel, NJ 08054-4620.

Emergency Information

: call 1-800-654-3282; US and 

Canada only.

Emergency First Aid Procedures

Toner swallowed (ingested)
Immediately seek medical attention. Never give anything by 
mouth to an unconscious person. If possible, rinse out 
mouth and give one or two glasses of water or milk to drink.
Toner inhaled.
Remove person to fresh air. Seek medical attention.
Toner gets in the eyes.
Flush eyes with large quantities of cool water for 15 minutes, 
keeping the eyelids open with fingers. If necessary, seek 
medical attention.
Toner gets on the skin.
Wash toner off the skin with plenty of cool water and soap. If 
necessary, seek medical attention.
Note: Small amounts of toner on skin or clothing can easily 

be removed with soap and 

cold

 water. Hot water 

makes toner harder to remove.

Hazardous Ingredients

Silica dioxide (about 2% by weight)

CAS#: Trade Secret.
OSHA PEL: Not established.
ACGIH TLV: Not established.
LD

50

: Not Available.

LC

50

: Not Available.

Physical Data

Physical State: Solid.
Melting/Freezing Point: Not available.
Boiling Point: Not available.
PH: Not available.
Vapor Pressure: Not available.
Vapor Density (Air=1): Not available.
Evaporation Rate (Butyl Acetate=1): Not available.
Specific Gravity (H

2

O=1): 1.1 to 1.2 at 20°C (68°F).

Solubility in Water: Not available.
Solubility in Solvents: Some components are soluble in 

toluene, chloroform and tetrahydrofuran.

Coefficient of water/oil Distribution: Not available.
Appearance and Odor: Yellow powder, no odor.
Odor Threshold: Not available.

Fire and Explosion Hazard Data ____

Minimal fire hazard. Large quantities may cause 

risk of dust explosion.

Flash Point (Method Used): Not applicable.
Flammable Limits

Lower Explosive Limit: Not available.
Upper Explosive Limit: Not available.

Auto-Ignition Temperature: Not available.
Explosion Data

Sensitivity to Mechanical Impact: Not available.
Sensitivity to Static Discharge: Not available.

Extinguishing Media: In case of small fire, use CO

2

. In 

case of large fire, shut off air by spraying with water or 
foam.

Special Fire Fighting Procedures: Fight fire from 

upwind position. Avoid inhalation of smoke or gases. Wear 
self-contained breathing apparatus.

Hazardous Combustion Products: Carbon monoxide, 

oxides of nitrogen.

Toxicological Properties

Routes of Entry: Inhalation, Ingestion, Eyes, Skin.
Effects of Acute Exposure: Not available.
Effects of Chronic Exposure: Not available.
Exposure Limits: Not available.
Irritancy: Not available.
Sensitivity: Not available.
Carcinogenicity

IARC:

 Silica Dioxide—Group 3. Not classifiable.

NTP:

 No components are listed.

OSHA:

 No components are listed.

Reproductive Toxicity: Not available.
Teratogenicity: Not available.
Mutagenicity: Not available.
Name of Toxicoligically Synergistic Products: Not 

available.

Reactivity Data

Stability: Stable in general.
Conditions to Avoid: Avoid excess heat and all sources of 

ignition.

Polymerization: Will not occur.
Hazardous Decomposition or Byproducts:

Combustion products include harmful gases such as carbon 
monoxide and nitrogen oxides.

Incompatibility: Not available.

 43866101 (C710)

Summary of Contents for C831

Page 1: ...ble in toluene chloroform and tetrahydrofuran Coefficient of water oil Distribution Not available Appearance and Odor Yellow powder no odor Odor Threshold Not available Fire and Explosion Hazard Data...

Page 2: ...ful Combustion can create harmful gases such as carbon monoxide and nitrogen oxides Large amounts must be passed to a licensed waste contractor Precautions Precautions for Handling or Storage Protect...

Page 3: ...chloroforme et le t trahydrofurane Coefficient de distribution eau huile Non disponible Aspect et odeur Poudre jaune inodore Seuil olfactif Non disponible Risques d incendie et d explosion __ Risque...

Page 4: ...ts de combustion incluent des gaz dangereux comme l oxyde de carbone et l oxyde d azote Les grandes quantit s doivent tre limin es dans une installation d limination homologu e Pr cautions Pr cautions...

Page 5: ...poraci n Acetato but lico 1 No procede Gravedad espec fica H2O 1 1 1 a 1 2 a 20 C 68 F Solubilidad en agua No procede Solubilidad en solventes Algunos componentes son solubles en tolueno cloroformo y...

Page 6: ...luego limpiar el resto con un trapo h medo Eliminaci n de Desechos Evitar la dispersi n del material en aguas limpias y alcantarillas Seguir las regulaciones federales estatales y locales pertinentes...

Page 7: ...pec fica H2O 1 1 1 a 1 2 a 20 C 68 F Solubilidade em gua N o dispon vel Solubilidade em solventes Alguns componentes s o sol veis em tolueno clorof rmio e tetrahidrofurano Coeficiente de distribui o d...

Page 8: ...urais de gua e esgotos Seguir as regulamenta es federais estaduais e locais aplic veis Pequenas quantidades podem ser incineradas Cuidado A combust o pode gerar gases perigosos tais como mon xido de c...