2
Measurement
FZ3 Processing Items List Manual
Precise Defect
223
Setting item
Set value
[Factory default]
Description
Profile
●
[Checked]
●
Unchecked
Set the profile display.
The maximum degree of defect along the X(circumferential) and
Y(radial) is displayed with red lines.
If you tap in the measurement region on the image area, the
profile in the XY directions from this point is displayed with yellow
lines.
Element
●
Checked
●
[Unchecked]
Set the comparison element display.
Elements are created automatically during measurement.The
density is calculated for each element and the position of defects/
contamination is detected from the degree of their variation.
Output Parameters (Precise Defect)
Specifies whether or not the judgement results of this processing unit is reflected in the scene overall
judgement.
1.
Tap [Output parameter] in the Item Tab area.
2.
Choose whether or not to reflect this in the scene overall judgement in "Reflect to overall
judgement" area.
Setting item
Set value
[Factory
default]
Description
Reflect to overall
judgement
●
[ON]
●
OFF
Enables choosing whether or not the judgement result of this
processing unit is reflected in the scene overall judgement.
Key Points for Test Measurement and Adjustment (Precise Defect)
The following content is displayed in the "Detail result" area as text.
Acesst 1.0 6251194
Summary of Contents for XPECTIA FZ3
Page 11: ...FZ3 Processing Items List Manual 9 Index 435 ...
Page 39: ...1 Input image FZ3 Processing Items List Manual Camera Image Input HDR 37 ...
Page 41: ...1 Input image FZ3 Processing Items List Manual Camera Switching 39 ...
Page 398: ...4 Support measurement 396 Iris FZ3 Processing Items List Manual ...
Page 410: ...5 Branch 408 DI Branch FZ3 Processing Items List Manual ...