Measurement
FZ3 Processing Items List Manual
267
Number of decoded
character
DN
Number of characters detected
Index
IDX
Index matched as the result of comparison with the classification
comparison character strings
About Output at PLC Link
1.
About output by b
If PLC link communication is performed, selecting the "Character output" check box among the
Output parameter will cause character string data to be output to the PLC link output area. (FZ3
Ver. 2.10 or later)
If 32 characters are read (read character string: 0123456789...UV), a continuous ASCII code
data string is output as shown below.
Output area
Top channel
Name
Output contents
+0ch
1st character,
2nd character
3031 (ASCII code corresponding to character "0," ASCII code
corresponding to character "1")
+1ch
3rd
character, 4th
character
3233 (ASCII code corresponding to character "2," ASCII code
corresponding to character "3")
・
・
・
+15ch
31st
character,
32nd
character
5556 (ASCII code corresponding to character "U," ASCII code
corresponding to character "V")
2.
How to receive character string data
As you do when serial data is output via PLC link, control the DSA data output request bit and
GATE data completion request bit.
Since the entire character string comprises 1 data, DSA control is performed once if there is only
1 unit.
Acesst 1.0 6251194
Summary of Contents for XPECTIA FZ3
Page 11: ...FZ3 Processing Items List Manual 9 Index 435 ...
Page 39: ...1 Input image FZ3 Processing Items List Manual Camera Image Input HDR 37 ...
Page 41: ...1 Input image FZ3 Processing Items List Manual Camera Switching 39 ...
Page 398: ...4 Support measurement 396 Iris FZ3 Processing Items List Manual ...
Page 410: ...5 Branch 408 DI Branch FZ3 Processing Items List Manual ...