1
Input
image
18
Camera Image Input
FZ3 Processing Items List Manual
2.
Set the start/end line in the "Number of lines to be read" area.
Electronic Flash Setting
This function is set when an electronic flash is used.This sets the output conditions for the signal for
synchronizing the measurement and the electronic flash timing.
1.
In the Item Tab area, tap [Camera setting].
2.
In the "Electronic flash setting" area, specify each item.
Item
Set value
[Factory default]
Description
STEP-STGOUT
delay
[0] to 511
(1 count 30μs)
Set the waiting time from the time the STEP signal is input
until the electronic flash trigger output signal comes ON.
Delay Time=Count x 30μs + 90μs
STGOUT
width
1 to 63
[3]
(1 count 30μs)
Set the output time for the electronic flash trigger signal.
STGOUT
polarity
●
[Positive]
●
Negative
Select the pulse polarity of the electronic flash trigger.
Positive polarity: Flashes synchronized with the timing of the
electronic flash trigger output signal changing from OFF to
ON.
Negative: Flashes when the strobe trigger output signal
changes from ON to OFF.
Screen Adjustment Settings (Camera Image Input)
Set the lighting and lens conditions for each camera.
●
Reference:
Lighting Control (p.19)
●
Reference:
Line Bright (p.21)
●
Reference:
Lens Adjustment Setting (p.21)
●
Reference:
Common Setting for All Cameras (p.22)
Acesst 1.0 6251194
Summary of Contents for XPECTIA FZ3
Page 11: ...FZ3 Processing Items List Manual 9 Index 435 ...
Page 39: ...1 Input image FZ3 Processing Items List Manual Camera Image Input HDR 37 ...
Page 41: ...1 Input image FZ3 Processing Items List Manual Camera Switching 39 ...
Page 398: ...4 Support measurement 396 Iris FZ3 Processing Items List Manual ...
Page 410: ...5 Branch 408 DI Branch FZ3 Processing Items List Manual ...