![background image](http://html.mh-extra.com/html/omron/xpectia-fz3/xpectia-fz3_user-manual_1633321223.webp)
2
Measurement
FZ3 Processing Items List Manual
Precise Defect
221
Note
●
Measurement mode
In Precise Defect measurement, the measurement mode depends on the number of registered region
figures and their types.The way to make elements depends on the measurement mode. The relationship
between the figure and measurement mode is as in the table below.
Single figure
Multiple
figures
Line
Circumference
Arc
Ellipse
Rectangle Polygon
Measurement
mode
Line
Wide circle
and arc
Wide circle
and arc
Region
Region
Region
Region
Line mode:
●
The direction parallel to the measurement region straight line is the X axis and the direction
perpendicular is the Y axis.The shape of elements is rectangular. The element width and length are
the number of pixels specified with the element size X and Y.
Wide circle and arc mode:
●
The circumferential direction along the measurement region wide circle (arc) is the X axis and the
radial direction is the Y axis.The shape of elements is fan-shaped. If the circumference length of the
wide circle (arc) of the measurement region is set to N, the element circumferential direction width is
360 degrees x the element size X / N. The element radial direction width is the number of pixels
specified with the element size Y. The element circumferential direction width is defined as an angle,
so the closer the element to the outer circumference, the larger the element.
Region mode:
●
The direction parallel to the measurement region is the X axis and the direction perpendicular is the
Y axis.The shape of elements is rectangular.The element width and length are the number of pixels
specified with the element size X and Y.
3.
If necessary, set the value of each item in the "Measurement condition" area.
Value input method: Reference:
See the "User's Manual", "Inputting Values" (p.313)
The "Area meas. LV" can be set also by dragging the slider or by tapping the buttons at the ends
of the slider.
For color cameras:
For monochrome cameras:
Acesst 1.0 6251194
Summary of Contents for XPECTIA FZ3
Page 11: ...FZ3 Processing Items List Manual 9 Index 435 ...
Page 39: ...1 Input image FZ3 Processing Items List Manual Camera Image Input HDR 37 ...
Page 41: ...1 Input image FZ3 Processing Items List Manual Camera Switching 39 ...
Page 398: ...4 Support measurement 396 Iris FZ3 Processing Items List Manual ...
Page 410: ...5 Branch 408 DI Branch FZ3 Processing Items List Manual ...