4
Support
measurement
FZ3 Processing Items List Manual
Calculation
337
achieved when both units 0 and 1 are judged as OK.
Judgement results of unit 0
(Judgement value)
Judgement results of unit 1
(Judgement value)
Expression result
(Summation results of
judgement values for units 0 and
1)
Judgement
result of
expression
OK (1)
OK (1)
2
OK
NG (-1)
OK (1)
0
NG
OK (1)
NG (-1)
0
NG
NG (-1)
NG (-1)
-2
NG
Using Values of Other Expressions
Up to 8 expressions can be set in 1 expression unit.
The value of other expressions set within the same unit can also be used.
Since expression results obtained by the expression are displayed as D00 to D07 and judgement results
of expression are displayed as J00 to J07, this is set to "U3.D00" (results of expression 0 set for
processing item [Calculation] of unit number "3") using "unit number calculation results".
For the following scene settings: